Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 12.242
Filtrar
1.
Biochem Med (Zagreb) ; 34(2): 020802, 2024 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-38665873

RESUMEN

We present two cases from the neonatal department with cerebrospinal fluid examination. We revealed a striking discrepancy in polymorphonuclear (PMN) and mononuclear (MN) cell counts using conventional light microscopy in comparison with automated analyzer Sysmex XN-1000 (PMNs - 13 vs. 173x106/L, MNs - 200 vs. 67x106/L in case 1 and PMNs - 13 vs. 372x106/L, MNs - 411 vs. 179x106/L in case 2). We revealed the dominant presence of hemosiderophages in both cases in cytospin slide. Even though Sysmex XN-1000 offers fast examination with a low sample volume, there is possibility of misdiagnosis, with negative impact on the patient.


Asunto(s)
Microscopía , Humanos , Recién Nacido , Microscopía/métodos , Masculino , Femenino , Neutrófilos/citología , Neutrófilos/patología , Líquido Cefalorraquídeo/citología , Recuento de Leucocitos , Leucocitos Mononucleares/patología , Leucocitos Mononucleares/citología
2.
ACS Sens ; 9(4): 2166-2175, 2024 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-38625680

RESUMEN

Relying on the strong optical absorption of hemoglobin to pulsed laser energy, photoacoustic microscopy provides morphological and functional information on microvasculature label-freely. Here, we propose speckle variance photoacoustic microscopy (SV-PAM), which harnesses intrinsic imaging contrast from temporal-varied photoacoustic signals of moving red blood cells in blood vessels, for recovering three-dimension hemodynamic images down to capillary-level resolution within the microcirculatory tissue beds in vivo. Calculating the speckle variance of consecutive photoacoustic B-scan frames acquired at the same lateral position enables accurate identification of blood perfusion and occlusion, which provides interpretations of dynamic blood flow in the microvasculature, in addition to the microvascular anatomic structures. We demonstrate high-resolution hemodynamic imaging of vascular occlusion and reperfusion in the microvasculature of mice ears in vivo. The results suggest that our SV-PAM is potentially invaluable for biomedical hemodynamic investigations, for example, imaging ischemic stroke and hemorrhagic stroke.


Asunto(s)
Microscopía , Técnicas Fotoacústicas , Técnicas Fotoacústicas/métodos , Animales , Ratones , Microscopía/métodos , Hemodinámica/fisiología , Oído/irrigación sanguínea , Oído/diagnóstico por imagen , Microvasos/diagnóstico por imagen , Eritrocitos , Microcirculación
3.
ACS Sens ; 9(4): 2134-2140, 2024 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-38626725

RESUMEN

Imaging the surface charge of biomolecules such as proteins and DNA, is crucial for comprehending their structure and function. Unfortunately, current methods for label-free, sensitive, and rapid imaging of the surface charge of single DNA molecules are limited. Here, we propose a plasmonic microscopy strategy that utilizes charge-sensitive single-crystal monolayer WS2 materials to image the local charge density of a single λ-DNA molecule. Our study reveals that WS2 is a highly sensitive charge-sensitive material that can accurately measure the local charge density of λ-DNA with high spatial resolution and sensitivity. The consistency of the surface charge density values obtained from the single-crystal monolayer WS2 materials with theoretical simulations demonstrates the reliability of our approach. Our findings suggest that this class of materials has significant implications for the development of label-free, scanning-free, and rapid optical detection and charge imaging of biomolecules.


Asunto(s)
ADN , ADN/química , Compuestos de Tungsteno/química , Microscopía/métodos
4.
Sichuan Da Xue Xue Bao Yi Xue Ban ; 55(2): 461-468, 2024 Mar 20.
Artículo en Chino | MEDLINE | ID: mdl-38645857

RESUMEN

Objective: To develop an artificial intelligence vaginal secretion analysis system based on deep learning and to evaluate the accuracy of automated microscopy in the clinical diagnosis of aerobic vaginitis (AV). Methods: In this study, the vaginal secretion samples of 3769 patients receiving treatment at the Department of Obstetrics and Gynecology, West China Second Hospital, Sichuan University between January 2020 and December 2021 were selected. Using the results of manual microscopy as the control, we developed the linear kernel SVM algorithm, an artificial intelligence (AI) automated analysis software, with Python Scikit-learn script. The AI automated analysis software could identify leucocytes with toxic appearance and parabasal epitheliocytes (PBC). The bacterial grading parameters were reset using standard strains of lactobacillus and AV common isolates. The receiver operating characteristic (ROC) curve analysis was used to determine the cut-off value of AV evaluation results for different scoring items were obtained by using the results of manual microscopy as the control. Then, the parameters of automatic AV identification were determined and the automatic AV analysis scoring method was initially established. Results: A total of 3769 vaginal secretion samples were collected. The AI automated analysis system incorporated five parameters and each parameter incorporated three severity scoring levels. We selected 1.5 µm as the cut-off value for the diameter between Lactobacillus and common AV bacterial isolates. The automated identification parameter of Lactobacillus was the ratio of bacteria ≥1.5 µm to those <1.5 µm. The cut-off scores were 2.5 and 0.5, In the parameter of white blood cells (WBC), the cut-off value of the absolute number of WBC was 103 µL-1 and the cut-off value of WBC-to-epithelial cell ratio was 10. The automated identification parameter of toxic WBC was the ratio of toxic WBC toWBC and the cut-off values were 1% and 15%. The parameter of background flora was bacteria<1.5 µm and the cut-off values were 5×103 µL-1 and 3×104 µL-1. The parameter of the parabasal epitheliocytes was the ratio of PBC to epithelial cells and the cut-off values were 1% and 10%. The agreement rate between the results of automated microscopy and those of manual microscopy was 92.5%. Out of 200 samples, automated microscopy and manual microscopy produced consistent scores for 185 samples, while the results for 15 samples were inconsistent. Conclusion: We developed an AI recognition software for AV and established an automated vaginal secretion microscopy scoring system for AV. There was good overall concordance between automated microscopy and manual microscopy. The AI identification software for AV can complete clinical lab examination with rather high objectivity, sensitivity, and efficiency, markedly reducing the workload of manual microscopy.


Asunto(s)
Inteligencia Artificial , Femenino , Humanos , Vagina/microbiología , Microscopía/métodos , Vaginosis Bacteriana/microbiología , Vaginosis Bacteriana/diagnóstico , Lactobacillus/aislamiento & purificación , Algoritmos , Curva ROC , Aprendizaje Profundo , Programas Informáticos
5.
Mol Biol Rep ; 51(1): 555, 2024 Apr 20.
Artículo en Inglés | MEDLINE | ID: mdl-38642192

RESUMEN

The eradication of Plasmodium parasites, responsible for malaria, is a daunting global public health task. It requires a comprehensive approach that addresses symptomatic, asymptomatic, and submicroscopic cases. Overcoming this challenge relies on harnessing the power of molecular diagnostic tools, as traditional methods like microscopy and rapid diagnostic tests fall short in detecting low parasitaemia, contributing to the persistence of malaria transmission. By precisely identifying patients of all types and effectively characterizing malaria parasites, molecular tools may emerge as indispensable allies in the pursuit of malaria elimination. Furthermore, molecular tools can also provide valuable insights into parasite diversity, drug resistance patterns, and transmission dynamics, aiding in the implementation of targeted interventions and surveillance strategies. In this review, we explore the significance of molecular tools in the pursuit of malaria elimination, shedding light on their key contributions and potential impact on public health.


Asunto(s)
Malaria , Parásitos , Plasmodium , Animales , Humanos , Malaria/epidemiología , Malaria/prevención & control , Salud Pública , Microscopía/métodos
6.
Opt Lett ; 49(7): 1725-1728, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38560847

RESUMEN

Ultrasound coupling is one of the critical challenges for traditional photoacoustic (or optoacoustic) microscopy (PAM) techniques transferred to the clinical examination of chronic wounds and open tissues. A promising alternative potential solution for breaking the limitation of ultrasound coupling in PAM is photoacoustic remote sensing (PARS), which implements all-optical non-interferometric photoacoustic measurements. Functional imaging of PARS microscopy was demonstrated from the aspects of histopathology and oxygen metabolism, while its performance in hemodynamic quantification remains unexplored. In this Letter, we present an all-optical thermal-tagging flowmetry approach for PARS microscopy and demonstrate it with comprehensive mathematical modeling and ex vivo and in vivo experimental validations. Experimental results demonstrated that the detectable range of the blood flow rate was from 0 to 12 mm/s with a high accuracy (measurement error:±1.2%) at 10-kHz laser pulse repetition rate. The proposed all-optical thermal-tagging flowmetry offers an effective alternative approach for PARS microscopy realizing non-contact dye-free hemodynamic imaging.


Asunto(s)
Técnicas Fotoacústicas , Tecnología de Sensores Remotos , Técnicas Fotoacústicas/métodos , Reología/métodos , Ultrasonografía/métodos , Microscopía/métodos
7.
Nat Commun ; 15(1): 2932, 2024 Apr 04.
Artículo en Inglés | MEDLINE | ID: mdl-38575577

RESUMEN

Ultrasound localization microscopy (ULM) enables deep tissue microvascular imaging by localizing and tracking intravenously injected microbubbles circulating in the bloodstream. However, conventional localization techniques require spatially isolated microbubbles, resulting in prolonged imaging time to obtain detailed microvascular maps. Here, we introduce LOcalization with Context Awareness (LOCA)-ULM, a deep learning-based microbubble simulation and localization pipeline designed to enhance localization performance in high microbubble concentrations. In silico, LOCA-ULM enhanced microbubble detection accuracy to 97.8% and reduced the missing rate to 23.8%, outperforming conventional and deep learning-based localization methods up to 17.4% in accuracy and 37.6% in missing rate reduction. In in vivo rat brain imaging, LOCA-ULM revealed dense cerebrovascular networks and spatially adjacent microvessels undetected by conventional ULM. We further demonstrate the superior localization performance of LOCA-ULM in functional ULM (fULM) where LOCA-ULM significantly increased the functional imaging sensitivity of fULM to hemodynamic responses invoked by whisker stimulations in the rat brain.


Asunto(s)
Aprendizaje Profundo , Microscopía , Ratas , Animales , Microscopía/métodos , Microburbujas , Ultrasonografía/métodos , Microscopía Intravital , Microvasos/diagnóstico por imagen
8.
Commun Biol ; 7(1): 451, 2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38622287

RESUMEN

This report presents an optical fibre-based endo-microscopic imaging tool that simultaneously measures the topographic profile and 3D viscoelastic properties of biological specimens through the phenomenon of time-resolved Brillouin scattering. This uses the intrinsic viscoelasticity of the specimen as a contrast mechanism without fluorescent tags or photoacoustic contrast mechanisms. We demonstrate 2 µm lateral resolution and 320 nm axial resolution for the 3D imaging of biological cells and Caenorhabditis elegans larvae. This has enabled the first ever 3D stiffness imaging and characterisation of the C. elegans larva cuticle in-situ. A label-free, subcellular resolution, and endoscopic compatible technique that reveals structural biologically-relevant material properties of tissue could pave the way toward in-vivo elasticity-based diagnostics down to the single cell level.


Asunto(s)
Imagenología Tridimensional , Microscopía , Animales , Microscopía/métodos , Imagenología Tridimensional/métodos , Caenorhabditis elegans , Elasticidad , Biología
9.
ACS Nano ; 18(16): 10738-10757, 2024 Apr 23.
Artículo en Inglés | MEDLINE | ID: mdl-38609349

RESUMEN

Biomolecular condensates play important roles in a wide array of fundamental biological processes, such as cellular compartmentalization, cellular regulation, and other biochemical reactions. Since their discovery and first observations, an extensive and expansive library of tools has been developed to investigate various aspects and properties, encompassing structural and compositional information, material properties, and their evolution throughout the life cycle from formation to eventual dissolution. This Review presents an overview of the expanded set of tools and methods that researchers use to probe the properties of biomolecular condensates across diverse scales of length, concentration, stiffness, and time. In particular, we review recent years' exciting development of label-free techniques and methodologies. We broadly organize the set of tools into 3 categories: (1) imaging-based techniques, such as transmitted-light microscopy (TLM) and Brillouin microscopy (BM), (2) force spectroscopy techniques, such as atomic force microscopy (AFM) and the optical tweezer (OT), and (3) microfluidic platforms and emerging technologies. We point out the tools' key opportunities, challenges, and future perspectives and analyze their correlative potential as well as compatibility with other techniques. Additionally, we review emerging techniques, namely, differential dynamic microscopy (DDM) and interferometric scattering microscopy (iSCAT), that have huge potential for future applications in studying biomolecular condensates. Finally, we highlight how some of these techniques can be translated for diagnostics and therapy purposes. We hope this Review serves as a useful guide for new researchers in this field and aids in advancing the development of new biophysical tools to study biomolecular condensates.


Asunto(s)
Condensados Biomoleculares , Condensados Biomoleculares/química , Condensados Biomoleculares/metabolismo , Microscopía de Fuerza Atómica , Pinzas Ópticas , Humanos , Microscopía/métodos
10.
J Biomed Opt ; 29(Suppl 2): S22704, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38584966

RESUMEN

Significance: Full-field optical coherence microscopy (FF-OCM) is a prevalent technique for backscattering and phase imaging with epi-detection. Traditional methods have two limitations: suboptimal utilization of functional information about the sample and complicated optical design with several moving parts for phase contrast. Aim: We report an OCM setup capable of generating dynamic intensity, phase, and pseudo-spectroscopic contrast with single-shot full-field video-rate imaging called bichromatic tetraphasic (BiTe) full-field OCM with no moving parts. Approach: BiTe OCM resourcefully uses the phase-shifting properties of anti-reflection (AR) coatings outside the rated bandwidths to create four unique phase shifts, which are detected with two emission filters for spectroscopic contrast. Results: BiTe OCM overcomes the disadvantages of previous FF-OCM setup techniques by capturing both the intensity and phase profiles without any artifacts or speckle noise for imaging scattering samples in three-dimensional (3D). BiTe OCM also utilizes the raw data effectively to generate three complementary contrasts: intensity, phase, and color. We demonstrate BiTe OCM to observe cellular dynamics, image live, and moving micro-animals in 3D, capture the spectroscopic hemodynamics of scattering tissues along with dynamic intensity and phase profiles, and image the microstructure of fall foliage with two different colors. Conclusions: BiTe OCM can maximize the information efficiency of FF-OCM while maintaining overall simplicity in design for quantitative, dynamic, and spectroscopic characterization of biological samples.


Asunto(s)
Microscopía , Tomografía de Coherencia Óptica , Animales , Microscopía/métodos , Tomografía de Coherencia Óptica/métodos , Microscopía de Contraste de Fase
11.
J Biomed Opt ; 29(Suppl 1): S11527, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38464883

RESUMEN

Significance: We developed a high-speed optical-resolution photoacoustic microscopy (OR-PAM) system using a high-repetition-rate supercontinuum (SC) light source and a two-axes Galvano scanner. The OR-PAM system enabled real-time imaging of optical absorbers inside biological tissues with excellent excitation wavelength tunability. Aim: In the near-infrared (NIR) wavelength range, high-speed OR-PAM faces limitations due to the lack of wavelength-tunable light sources. Our study aimed to enable high-speed OR-PAM imaging of various optical absorbers, including NIR contrast agents, and validate the performance of high-speed OR-PAM in the detection of circulating tumor cells (CTCs). Approach: A high-repetition nanosecond pulsed SC light source was used for OR-PAM. The excitation wavelength was adjusted by bandpass filtering of broadband light pulses produced by an SC light source. Phantom and in vivo experiments were performed to detect tumor cells stained with an NIR contrast agent within flowing blood samples. Results: The newly developed high-speed OR-PAM successfully detected stained cells both in the phantom and in vivo. The phantom experiment confirmed the correlation between the tumor cell detection rate and tumor cell concentration in the blood sample. Conclusions: The high-speed OR-PAM effectively detected stained tumor cells. Combining high-speed OR-PAM with molecular probes that stain tumor cells in vivo enables in vivo CTC detection.


Asunto(s)
Dispositivos Ópticos , Técnicas Fotoacústicas , Microscopía/métodos , Técnicas Fotoacústicas/métodos , Análisis Espectral , Fantasmas de Imagen
12.
Nat Commun ; 15(1): 2679, 2024 Mar 27.
Artículo en Inglés | MEDLINE | ID: mdl-38538644

RESUMEN

In 2015, we launched the mesoSPIM initiative, an open-source project for making light-sheet microscopy of large cleared tissues more accessible. Meanwhile, the demand for imaging larger samples at higher speed and resolution has increased, requiring major improvements in the capabilities of such microscopes. Here, we introduce the next-generation mesoSPIM ("Benchtop") with a significantly increased field of view, improved resolution, higher throughput, more affordable cost, and simpler assembly compared to the original version. We develop an optical method for testing detection objectives that enables us to select objectives optimal for light-sheet imaging with large-sensor cameras. The improved mesoSPIM achieves high spatial resolution (1.5 µm laterally, 3.3 µm axially) across the entire field of view, magnification up to 20×, and supports sample sizes ranging from sub-mm up to several centimeters while being compatible with multiple clearing techniques. The microscope serves a broad range of applications in neuroscience, developmental biology, pathology, and even physics.


Asunto(s)
Microscopía , Neurociencias , Microscopía/métodos
13.
Comput Biol Med ; 172: 108167, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38461699

RESUMEN

In recent decades, many studies have been published on the use of automatic smear microscopy for diagnosing pulmonary tuberculosis (TB). Most of them deal with a preliminary step of the diagnosis, the bacilli detection, whereas sputum smear microscopy for diagnosis of pulmonary TB comprises detecting and reporting the number of bacilli found in at least 100 microscopic fields, according to the 5 grading scales (negative, scanty, 1+, 2+ and 3+) endorsed by the World Health Organization (WHO). Pulmonary TB diagnosis in bright-field smear microscopy, however, depends upon the attention of a trained and motivated technician, while the automated TB diagnosis requires little or no interpretation by a technician. As far as we know, this work proposes the first automatic method for pulmonary TB diagnosis in bright-field smear microscopy, according to the WHO recommendations. The proposed method comprises a semantic segmentation step, using a deep neural network, followed by a filtering step aiming to reduce the number of false positives (false bacilli): color and shape filtering. In semantic segmentation, different configurations of encoders are evaluated, using depth-wise separable convolution layers and channel attention mechanism. The proposed method was evaluated with a large, robust, and annotated image dataset designed for this purpose, consisting of 250 testing sets, 50 sets for each of the 5 TB diagnostic classes. The following performance metrics were obtained for automatic pulmonary TB diagnosis by smear microscopy: mean precision of 0.894, mean recall of 0.896, and mean F1-score of 0.895.


Asunto(s)
Mycobacterium tuberculosis , Tuberculosis Pulmonar , Humanos , Microscopía/métodos , Tuberculosis Pulmonar/diagnóstico por imagen , Redes Neurales de la Computación , Sensibilidad y Especificidad
14.
Proc Natl Acad Sci U S A ; 121(12): e2304866121, 2024 Mar 19.
Artículo en Inglés | MEDLINE | ID: mdl-38483992

RESUMEN

Accelerating the measurement for discrimination of samples, such as classification of cell phenotype, is crucial when faced with significant time and cost constraints. Spontaneous Raman microscopy offers label-free, rich chemical information but suffers from long acquisition time due to extremely small scattering cross-sections. One possible approach to accelerate the measurement is by measuring necessary parts with a suitable number of illumination points. However, how to design these points during measurement remains a challenge. To address this, we developed an imaging technique based on a reinforcement learning in machine learning (ML). This ML approach adaptively feeds back "optimal" illumination pattern during the measurement to detect the existence of specific characteristics of interest, allowing faster measurements while guaranteeing discrimination accuracy. Using a set of Raman images of human follicular thyroid and follicular thyroid carcinoma cells, we showed that our technique requires 3,333 to 31,683 times smaller number of illuminations for discriminating the phenotypes than raster scanning. To quantitatively evaluate the number of illuminations depending on the requisite discrimination accuracy, we prepared a set of polymer bead mixture samples to model anomalous and normal tissues. We then applied a home-built programmable-illumination microscope equipped with our algorithm, and confirmed that the system can discriminate the sample conditions with 104 to 4,350 times smaller number of illuminations compared to standard point illumination Raman microscopy. The proposed algorithm can be applied to other types of microscopy that can control measurement condition on the fly, offering an approach for the acceleration of accurate measurements in various applications including medical diagnosis.


Asunto(s)
Microscopía , Espectrometría Raman , Humanos , Microscopía/métodos , Espectrometría Raman/métodos , Glándula Tiroides , Microscopía Óptica no Lineal , Aprendizaje Automático
15.
Nanoscale ; 16(12): 6190-6198, 2024 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-38445876

RESUMEN

Here we introduce scattering-type scanning near-field optical microscopy (s-SNOM) as a novel tool for nanoscale chemical-imaging of sub-cellular organelles, nanomaterials and of the interactions between them. Our setup uses a tuneable mid-infrared laser and a sharp scanning probe to image at a resolution substantially surpassing the diffraction limit. The laser can be tuned to excite vibrational modes of functional groups in biomolecules, (e.g. amide moieties), in a way that enables direct chemical mapping without the need for labelling. We, for the first time, chemically image neuronal ultrastructure, identify neuronal organelles and sub-organelle structures as small as 10 nm and validate our findings using transmission electron microscopy (TEM). We produce chemical and morphological maps of neurons treated with gold nanospheres and characterize nanoparticle size and intracellular location, and their interaction with the plasma membrane. Our results show that the label-free nature of s-SNOM means it has a 'true' chemical resolution of up to 20 nm which can be further improved. We argue that it offers significant potential in nanomedicine for nanoscale chemical imaging of cell ultrastructure and the subcellular distribution of nanomaterials within tissues.


Asunto(s)
Nanopartículas , Nanoestructuras , Nanotecnología/métodos , Microscopía/métodos , Nanoestructuras/química , Luz
16.
Elife ; 122024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-38488831

RESUMEN

Nondestructive pathology based on three-dimensional (3D) optical microscopy holds promise as a complement to traditional destructive hematoxylin and eosin (H&E) stained slide-based pathology by providing cellular information in high throughput manner. However, conventional techniques provided superficial information only due to shallow imaging depths. Herein, we developed open-top two-photon light sheet microscopy (OT-TP-LSM) for intraoperative 3D pathology. An extended depth of field two-photon excitation light sheet was generated by scanning a nondiffractive Bessel beam, and selective planar imaging was conducted with cameras at 400 frames/s max during the lateral translation of tissue specimens. Intrinsic second harmonic generation was collected for additional extracellular matrix (ECM) visualization. OT-TP-LSM was tested in various human cancer specimens including skin, pancreas, and prostate. High imaging depths were achieved owing to long excitation wavelengths and long wavelength fluorophores. 3D visualization of both cells and ECM enhanced the ability of cancer detection. Furthermore, an unsupervised deep learning network was employed for the style transfer of OT-TP-LSM images to virtual H&E images. The virtual H&E images exhibited comparable histological characteristics to real ones. OT-TP-LSM may have the potential for histopathological examination in surgical and biopsy applications by rapidly providing 3D information.


Asunto(s)
Microscopía , Neoplasias , Masculino , Humanos , Microscopía/métodos , Colorantes Fluorescentes , Piel , Eosina Amarillenta-(YS) , Imagenología Tridimensional/métodos
17.
J Biomed Opt ; 29(3): 036502, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38515831

RESUMEN

Significance: The reprojection setup typical of oblique plane microscopy (OPM) limits the effective aperture of the imaging system, and therefore its efficiency and resolution. Large aperture system is only possible through the use of custom specialized optics. A full-aperture OPM made with off the shelf components would both improve the performance of the method and encourage its widespread adoption. Aim: To prove the feasibility of an OPM without a conventional reprojection setup, retaining the full aperture of the primary objective employed. Approach: A deformable lens based remote focusing setup synchronized with the rolling shutter of a complementary metal-oxide semiconductor detector is used instead of a traditional reprojection system. Results: The system was tested on microbeads, prepared slides, and zebrafish embryos. Resolution and pixel throughput were superior to conventional OPM with cropped apertures, and comparable with OPM implementations with custom made optical components. Conclusions: An easily reproducible approach to OPM imaging is presented, eliminating the conventional reprojection setup and exploiting the full aperture of the employed objective.


Asunto(s)
Lentes , Dispositivos Ópticos , Animales , Microscopía/métodos , Pez Cebra , Óptica y Fotónica , Óxidos
18.
Sci Adv ; 10(12): eadk1278, 2024 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-38507481

RESUMEN

Studying placental functions is crucial for understanding pregnancy complications. However, imaging placenta is challenging due to its depth, volume, and motion distortions. In this study, we have developed an implantable placenta window in mice that enables high-resolution photoacoustic and fluorescence imaging of placental development throughout the pregnancy. The placenta window exhibits excellent transparency for light and sound. By combining the placenta window with ultrafast functional photoacoustic microscopy, we were able to investigate the placental development during the entire mouse pregnancy, providing unprecedented spatiotemporal details. Consequently, we examined the acute responses of the placenta to alcohol consumption and cardiac arrest, as well as chronic abnormalities in an inflammation model. We have also observed viral gene delivery at the single-cell level and chemical diffusion through the placenta by using fluorescence imaging. Our results demonstrate that intravital imaging through the placenta window can be a powerful tool for studying placenta functions and understanding the placental origins of adverse pregnancy outcomes.


Asunto(s)
Placenta , Placentación , Embarazo , Femenino , Ratones , Animales , Placenta/diagnóstico por imagen , Microscopía/métodos , Imagen Óptica , Microscopía Intravital
19.
Toxicol Lett ; 394: 92-101, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38428546

RESUMEN

Functionalized nanoparticles have been developed for use in nanomedicines for treating life threatening diseases including various cancers. To ensure safe use of these new nanoscale reagents, various assays for biocompatibility or cytotoxicity in vitro using cell lines often serve as preliminary assessments prior to in vivo animal testing. However, many of these assays were designed for soluble, colourless materials and may not be suitable for coloured, non-transparent nanoparticles. Moreover, cell lines are not always representative of mammalian organs in vivo. In this work, we use non-invasive impedance sensing methods with organotypic human liver HepaRG cells as a model to test the toxicity of PEG-Fe3O4 magnetic nanoparticles. We also use Coherent anti-Stokes Raman Spectroscopic (CARS) microscopy to monitor the formation of lipid droplets as a parameter to the adverse effect on the HepaRG cell model. The results were also compared with two commercial testing kits (PrestoBlue and ATP) for cytotoxicity. The results suggested that the HepaRG cell model can be a more realistic model than commercial cell lines while use of impedance monitoring of Fe3O4 nanoparticles circumventing the uncertainties due to colour assays. These methods can play important roles for scientists driving towards the 3Rs principle - Replacement, Reduction and Refinement.


Asunto(s)
Nanopartículas de Magnetita , Microscopía , Animales , Humanos , Microscopía/métodos , Nanopartículas de Magnetita/toxicidad , Impedancia Eléctrica , Espectrometría Raman/métodos , Hígado , Mamíferos
20.
Nat Commun ; 15(1): 1940, 2024 Mar 02.
Artículo en Inglés | MEDLINE | ID: mdl-38431671

RESUMEN

Volumetric super-resolution microscopy typically encodes the 3D position of single-molecule fluorescence into a 2D image by changing the shape of the point spread function (PSF) as a function of depth. However, the resulting large and complex PSF spatial footprints reduce biological throughput and applicability by requiring lower labeling densities to avoid overlapping fluorescent signals. We quantitatively compare the density dependence of single-molecule light field microscopy (SMLFM) to other 3D PSFs (astigmatism, double helix and tetrapod) showing that SMLFM enables an order-of-magnitude speed improvement compared to the double helix PSF by resolving overlapping emitters through parallax. We demonstrate this optical robustness experimentally with high accuracy ( > 99.2 ± 0.1%, 0.1 locs µm-2) and sensitivity ( > 86.6 ± 0.9%, 0.1 locs µm-2) through whole-cell (scan-free) imaging and tracking of single membrane proteins in live primary B cells. We also exemplify high-density volumetric imaging (0.15 locs µm-2) in dense cytosolic tubulin datasets.


Asunto(s)
Imagenología Tridimensional , Microscopía , Microscopía/métodos , Imagenología Tridimensional/métodos , Imagen Individual de Molécula/métodos , Nanotecnología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...